国产亚洲欧美精品一区二区三区-亚洲欧美精品中文字幕-成年视频国产免费观看-国产免费一区、二区丶三区

,Welcome to Weihai Kangzheng Medical!
Support Hotline:0631-5768777 | CHINESE | ENGLISH
Support Hotline
0631-5768777
Company Fax
0631-5674466
E-Mail
whkangzheng@163.com
Common Problem

Medical equipment tips - the use of blood glucose meter Note

Source: Time:2011-05-18 16:47:42 views:

In the use of blood glucose meter occasionally there will be some of the situation, can not be normal blood glucose measurement, in addition to the purchase of the correct use of the correct use of the method, the following to introduce a few blood glucose meter use points
In the use of blood glucose meter occasionally there will be some of the situation, can not be normal blood glucose measurement, in addition to the purchase of the correct use of the correct use of the method, the following to introduce a few blood glucose meter use points:
1, blood glucose test code of each batch are not the same, should be checked before the test, adjust the blood glucose meter display code and test strip box code, so consistent. March 1, 2008, the US FDA to remind professional health care providers and blood glucose meter users: the best use of blood glucose meter and supporting the test paper, and in the use of carefully read the use of guidelines. If you are not using a matching test paper, the blood glucose meter may not work properly or the test results are incorrect.
2, test strip of the validity of the problem: check the validity of the test paper before use. At present, most of the test strips are only valid for about three months after the test paper bottle is opened, so the opening date is marked above when opening a new test paper.
3, try to save the paper: test paper to avoid moisture, should be placed in a dry, cool, dark place, sealed with a closed. Store the test strip in the original box and do not hold it in other containers.
4, improper blood collection methods: test if the lack of blood, will lead to failure or low test results. Such as blood drops too large, overflow measurement area, will also affect the determination of the results. You should use a new test strip in the test area drops of blood to confirm the back of the test strip "blood to confirm the dot" completely discolored. In addition, blood collection due to acral peripheral circulation is not good, poor blood flow or excessive extrusion will also affect the determination of the results.
5, take blood after disinfection of residual alcohol: the best disinfectant alcohol and then take blood.
6, blood glucose meter is not clean: test blood sugar, often by the environment of dust, fiber, debris pollution, especially when the test is not careful to pollute the blood of the instrument test area, will affect the test results.
7, after the error repeatedly insert the test paper: When the test paper after the blood glucose meter prompts wrong or can not be normal boot, do not be too impatient to insert the test paper, the same test paper inserted more than three times can not be used. Follow the prompt code solution in the manual for proper handling.
Before buying a blood glucose meter to seriously consult, choose after-sales service is good, suitable for their own blood glucose meter. Master the correct method of operation, and develop a good habit of recording blood sugar levels, with medical staff treatment.


keys: 
Home   |  About Us   |  Products   |  News   |  Certificates   |  Clients   |  Jobs   |  Contact Us   | 
Address::Western Zone Sunjiatan Village Town Weihai Shandong Province       TEL:0631-5768777    FAX:0631-5674466     E-MAIL:whkangzheng@163.com    Zip code: 264200
Copyright ©2017  Weihai Kangzheng Medical Equipment Technology Co., Ltd  All rights reserved  Technical Support:Weihai Leixun online